AMETEK

AMETEK-CTS is a global leader in EMC compliance testing and RF power amplifiers. AMETEK has been designing and manufacturing precision instruments for more than 30 years.  Under the brand names of EM Test, Teseq, IFI and Milmega the company produce a wide range of specialist solutions aligned to the individual needs of equipment manufacturers across a variety of industries.
These include:

  • Automotive
  • Aerospace and Defense
  • Consumer electronics
  • Household appliances
  • Medical devices
  • Renewable energy

From its design and manufacturing facilities in Switzerland, Germany, the United States and the UK, AMETEK CTS provides customers with innovative solutions to the complex requirements of EMC compliance standards.

Due to the global impact of Covid19 that has been declared pandemic by WHO, there are medical electrical equipment such as ventilators etc. that requires EMC Testing. Glad to be informed that AMETEK provides the solution for this need.

Under the Standard Guideline of IEC 60601-1-2 (Ed. 4, 2014), medical product needs to go through Electromagnetic Disturbances (Emission and Immunity) testing and our equipments satisfy the standard requirement.

EMISSIONS

Emission
• Mains Terminal Disturbance Voltage
• Electromagnetic Radiation Disturbance
• Harmonic Current Emission IEC 61000-3-2
• Voltage Changes, Fluctuations and Flicker


CISPRII
CISPR 11
IEC 61000-3-2
IEC 61000-3-3 

• Most of the standard concem’s immunity due to safety considerations
• It is however also important for the safety of patients to control emissions to prevent interference with other medical equipment

SUITABLE EQUIPMENT

IEC 61000-3-2 and IEC 61000-3-3 apply to medical Equipment and Systems intended for use in the Home Healthcare Environment if both:

  • DPA 500N (analyser)
  • Netwave 7 or ACS 500N6 (electronic source)
Netwave 7 or ACS 500N6 (electronic sources)
Netwave 7 or ACS 500N6 (electronic sources)
DPA 500N (analyser)

IMMUNITY

Immunity
• Electrostatic Discharge, ESD
• Radiated RF Electromagnetic Field
• Electrical Fast Transients/Burst
• Surge Immunity
• Conducted Disturbance by RF Fields
• Power Frequency Magnetic Fields
• Voltage Dips, variations and Interruptions, Power Fail


IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11

suitable equipment

IEC 61000-4-2: Electrostatic Discharge, ESD 

  • Various models available:
  • Dito / esd NX30 / NSG 435 / NSG 438
  • EAS 30 (grounding resistor)
Dito
ESD NX30
NSG 435
NSG 438
EAS 30 (grounding resistor)

IMMUNITY - SUITABLE EQUIPMENT FROM AMETEK CTS

• IEC 61000-4-4: Electrical Fast Transient/Burst

Various models available:
• Compacr NX5 / NSG 3040A
• CCI (Capacitive Coupling Clamp)

Compact NX5
NSG 3040A
CCI (capacitive coupling clamp)

• IIEC 61000-4-5: Surge Immunity

Various models available:
• Compact NX5 / NSG 3040A
• DCD 5 sr / NSG 117A (coupling network I/O-lines)

Compact NX5
NSG 3040A
DCD 5 sr
NSG 117A

suitable equipment

• IEC 61000-4-6: Conducted Disturbance by RF Fields

Various models available:
• NSG 4070C
• CDNs / EM Clamp

NSG 4070C
CDNs
EM Clamp

• IEC 61000-4-8: Power Frequency Magnetic Fields

Various models available:
• MFG 40-100 (magnetic field generator)
• MFC 30 / MFC 300 (multi-turn antennas)

MFG 40-100 (magnetic field generator)
MFC 300 (multi-turn antennas)
MFC 30

Immunity – suitable equipment from AMETEK CTS

• IEC 61000-4-8: Power Frequency Magnetic Fields

Various models available:
• Variac NX / VAR 3005A-S16  (motorized variac)
• MFT 30 (current transformer up to 30 A/m)
• MFC 1000 / MFC 1000.1 (single-turn antennas)

variac NX / VAR 3005A-S16 (motorized variac)
MFT 30 (current transformer up to 30 A/m)
MFC 1000 / MFC 1000.1 (single-turn antennas)

• IEC 61000-4-11: Voltage Dips, variations and Interruptions, Power Fail

Various models available:
• Variac NX / VAR 3005A-S16  (motorized variac)
• Alternatively: TVT 1-250-16 (tapped transformer)

variac NX
VAR 3005A-S16 (motorized variac)
alternatively: TVT 1-250-16 (tapped transformer)

Products

Electrostatic Discharge Simulator

​​Electrostatic Discharge Simulator up to 30 kV​

Highlights

  • Test voltage up to 30 kV for air and contact discharge
  • Color touch display
  • Discharges up to 25 Hz
    80 easy-to-change R/C-networks and tips
  • Switchable Bleed-Off function
  • Built-in activity log
  • AC mains supply and DC supply
  • Battery tested to 30,000 pulses @30 kV
  • Built-in selftest function
  • USB-interface
  • Control and analyzing-software for Windows 7
  • Optional fiber optic link between esd NX30 and computer (USB port)
Multifunctional Test Generator for Transients

Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV

Highlights

  • Smallest compact generator with 7″ touch screen
  • Burst 5.5 kV, Surge 5.0 kV and Power Fail
  • Built-in single phase CDN 400 V/32 A
  • Manual front panel operation with setup pictures
  • Separate key for START/STOP operation with LED
  • Monitor outputs for peak voltage and current
  • Opto-Link and Ethernet for remote control
  • Control of external three-phase couplers
  • Module PowerFail as per IEC/EN 61000-4-8/-11/-29(DC)
  • Fail inputs
ProfLine

ProfLine 2105

  • Complete test system for IEC 61000-3-2 and -3-3
  • Single phase system up to 16 A
  • Simulated flicker impedance, no need for expensive physical impedance
  • Power source suitable for testing to immunity standards